Specification |
Power Supply |
6.0kW AC Power Supply |
7.5kW AC Power Supply |
Chassis compatibility |
• Cisco Nexus 7010 (up to 3)
• Cisco Nexus 7018 (up to 4) |
Software compatibility |
Cisco® NX-OS Software Release 4.0 and later |
Cisco NX-OS Software Release 4.1(2) and later |
Physical specifications |
• (H x W x D): 8.51* x 4 x 17.5 in. (21.6 x 10.1 x 44.5 cm)
• Weight: 18 lb (8.2 kg)
• * The height of the power supply unit is not uniform along the entire depth. The height at the front and rear are 8.51 and 4.2 in. (21.6 and 10.7 cm) respectively. |
• (H x W x D): 8.51* x 4 x 17.5 in. (21.6 x 10.1 x 44.5 cm)
• Weight: 23 lb (10.5 kg)
• * The height of the power supply unit is not uniform along the entire depth. The height at the front and rear are 8.51 and 4.2 in. (21.6 and 10.7 cm) respectively. |
Input voltage range |
90 to 264 VAC |
170 to 264V AC |
Input frequency range |
47 to 63 Hz |
47 to 63 Hz |
Input current (each input) |
16A maximum at nominal line voltage (110 or 220 VAC) |
24A maximum at nominal line voltage (220 VAC) |
Power supply input receptacles |
International Electrotechnical Commission (IEC) 320-C19 |
IEC 60309 for INT
NEMA L6-30 for US |
Power cord rating |
16A |
24A |
British thermal units (BTUs) |
• 23,000 BTUs per hour at 6000W
• 16,500 BTUs per hour at 4200W
• 11,500 BTUs per hour at 3000W
• 9900 BTUs per hour at 2400W
• 4950 BTUs per hour at 1200W |
• 28500 BTUs per hour at 7500W
• 14200 BTUs per hour at 3750W |
Mean time between failure (MTBF) |
341,356 hours |
204,053 hours |
Output holdup time |
20 milliseconds (ms) minimum |
Cooling fan |
Integrated |
Environmental conditions |
• Operating temperature: 32 to 104°F (0 to 40°C)
• Storage temperature: -40 to 185°F (-40C to 85°C)
• Relative humidity operating, noncondensing: 10 to 90%
• Relative humidity nonoperating, noncondensing: 10 to 95% |
Regulatory compliance |
• EMC compliance
• FCC Part 15 (CFR 47) (USA) Class A
• ICES-003 (Canada) Class A
• EN55022 (Europe) Class A
• CISPR22 (International) Class A
• AS/NZS CISPR22 (Australia and New Zealand) Class A
• VCCI (Japan) Class A
• KN22 (Korea) Class A
• CNS13438 (Taiwan) Class A
• CISPR24
• EN55024
• EN50082-1
• EN61000-3-2
• EN61000-3-3
• EN61000-6-1
• EN300 386 |
|
Environmental standards |
• NEBS criteria levels
• SR-3580 NEBS Level 3 (GR-63-CORE, issue 3, and GR-1089-CORE, issue 4)
• Verizon NEBS compliance
• Telecommunications Carrier Group (TCG) Checklist
• Qwest NEBS requirements
• Telecommunications Carrier Group (TCG) Checklist
• ATT NEBS requirements
• ATT TP76200 level 3 and TCG Checklist
• ETSI
• ETS 300 019-1-1, Class 1.2 Storage
• ETS 300 019-1-2, Class 2.3 Transportation
• ETS 300 019-1-3, Class 3.2 Stationary Use
• Reduction of Hazardous Substances (ROHS) 5 |
Safety compliance |
• Ul/CSA/IEC/EN 60950-1
• AS/NZS 60950 |
LED indicators |
• Green "Input 1 OK" LED: On when AC voltage in input 1 is within the valid range.
• Green "Input 2 OK" LED: On when AC voltage in input 2 is within the valid range.
• Green "Output OK" LED: On when the DC outputs are within the valid range and stable.
• Red "Fault" LED: On and blinking when the power supply's internal self-diagnostics have failed or any other power supply failure has occurred.
• Blue "ID" LED: On and blinking when the operator has flagged this card for identification. |
Reliability and availability |
Capable of online insertion and removal (OIR) |
MIBs |
Supports Simple Network Management Protocol Versions 3, 2, and 1 (see Cisco NX-OS Software release notes for details about specific MIB support) |
Warranty |
Cisco Nexus 7000 Series Switches come with the standard Cisco 1-Year Limited Hardware Warranty |